Smart Online UPS system with isolation transformer and pure sinewave output
The Smartbitt SBOL6KT-2 online, two-phase UPS system combines unprecedented efficiency, reliability and scalability with the latest technologies to keep up with the growing energy demands of information-driven infrastructures. It utilizes double-conversion topology to provide seamless pure sine wave output to mission-critical applications, data servers and network equipment, preventing –as a result– costly downtime, data loss/corruption, process interruption and hardware damage. Monitoring is simplified by a state-of-the art multifunction LCD display that provides access to configuration tools, system information and the operation status of the UPS in real time. This series brings a robust combination of low input current distortion, a wide voltage regulation range and power factor correction (PFC) capabilities for reduced utility costs, increased uptime and cooler operating conditions. With unparallel efficiency and capacity ratings of 6kVA, this system meets the rapidly evolving power density requirements in both centralized and edge-of-network platforms.
MODEL SBOL6KT-2
Fase → Bifásico con toma de tierra
Capacidad → 6000VA/5400W
Conexiones → Hard Wired (Cableado Permanente)
Tiempo de Respaldo → Carga completa 6 min. /Media carga 15 min.
INPUT
Voltaje nominal → 208/220/230/240 VAC
Rango de voltaje → 110-300 VAC a 50% carga
Rango de frecuencia → 46~54 Hz 0 50 Hz / 56~64 Hz 0 60 Hz
Factor de poder → ≧ 0.99 @ (100% Carga)
OUTPUT
Voltaje de salida → 100/110/120/208/220/230/240 VAC
Regulación de Voltaje → ±1%
Rango de Frecuencia (Rango de sincronización) → 46~54 Hz o 56~64 Hz
Rango de frecuencia (Modo Batería) → 50 Hz ± 0.1 Hz o 60Hz ± 0.1 Hz
Rango cresta actual → 3:1 (max)
Distorsión Armónica → ≤3% THD (Línea de carga), ≤6% THD (Carga no lineal)
Tiempo de transferencia Modo AC a Modo de batería → Cero
Tiempo de transferencia Inversor a Bypass → Cero
Tipo de onda (Modo batería) → Simulación forma senoidal
EFFICIENCY
Modo AC
Modo Batería
BATTERY
Nombre y tipo de batería → 12 V 7.5 Ah x 2
Tiempo de ejecución a media carga → 7 min.
Tiempo de ejecución tipico@1PC+17” Monitor LCD → 60 min.
Tiempo de carga típica → 8 Horas
Números Corriente de carga (máx.)
Voltaje de carga Indicadores Panel LCD
ALARM
Modo
INTERFACE
Display → LED
Puerto USB compatible con HID → Sí
RJ45/11→ Sí
PHYSICAL CHARACTERISTICS
Factor de forma → Torre
Dimensiones (mm) → 320 x 130 x 182
Peso (Kg) → 11.00
AMBIENTAL
Temperatura → +32º F a 104º F / 0º C a 40º C
Humedad → 0-90 % (no condensada)
Elevación → 0-3000 metros
Temperatura de almacenamiento → -4ºF a 122º F / -20º C a 50º C
Temperatura de humedad → 0% – 90%
Temperatura de elevación → 0-3000 metros
Ruido audible a 1.5m de la superficie de la unidad → Menor que 45 dB
*El tiempo de respaldo puede variar dependiendo de la carga conectada
MANAGEMENT
Smart RS-232/USB →Soporta Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, y MAC
SNMP Opcional →Monitoreo y administración de UPS, vía SNMP por internet
Online topology for greater peace of mind
Since this is the only topology that offers zero-transfer time to and from battery mode, it affords the highest level of protection against the most critical power problems
Advanced power protection
Stay protected, connected, and safe with outlets providing surge suppression, voltage regulation and noise filtering capabilities
Maximize productivity
Keep your connected devices performing at their best, uninterrupted, and more reliably over time
Backup time
Standard integrated batteries offer around 10 minutes* of runtime at half load
Operational reliability
Output power factor of 0.9, frequency-conversion mode and generator compatible
Flexible, scalable architecture
Allows the connection of external battery banks for added redundancy and the future expansion of the UPS capacity to keep up with changing energy demands
Dedicated monitoring software
Enhanced communication and control capabilities offer improved visibility and management of the system, whether remotely or on site
Enterprise-grade quality
Experience the advantages of a robust construction, resulting in simplified maintenance and reduced cost of ownership
*Runtimes may vary depending on the battery level and the quantity of the connected loads
Recommended applications
– Full-sized enterprise
– Network server rooms
– Medium-sized medical equipment
– Data centers
– Industrial controls and automation
– Core network equipment
– High-performance computer systems and workstations
– VoIP infrastructures
– Critical-operation facilities